ABO valve has expanded its Fire Safe certification to the complete butterfly valve Series 2E Fire Safe and 3E portfolio, providing certified solutions for applications where fire safety is critical.

Why is Fire Safe certification important?

In critical industrial operations, small details can make a significant difference during emergency situations. That is why Fire Safe certification is increasingly specified in new projects. It confirms that the valve has been tested in accordance with international standards and is designed to maintain its sealing function even in the event of a fire.

Fire Safe butterfly valves are widely used in power generation, the chemical and petrochemical industries, refineries, gas distribution, and other applications where safety is a key criterion when selecting shut-off valves.

ChatGPT-Image-21.-7.-2026-12_20_12
How-is-fire-safe-test-performed

How is a Fire Safe test performed?

The tests are conducted by an accredited third-party laboratory and confirmed the valve’s ability to maintain its integrity and sealing performance under fire conditions, meeting the stringent requirements of both international standards - API 607 and ISO 10497.

To obtain Fire Safe certification, the valve must successfully pass a demanding fire test that simulates real fire conditions. The butterfly valve is installed in a pressurized test pipeline and placed inside a furnace, where it is exposed to temperatures of up to 1,000 °C for 30 minutes. During the test, leakage is continuously monitored, and any media leakage must remain within the limits specified by the applicable standard. According to ISO 10497, the maximum allowable leakage for a DN200 valve is 800 ml per minute. Our valve recorded zero leakage throughout the test, significantly exceeding the requirements of both standards.

After the fire exposure, the valve undergoes controlled cooling followed by an operational inspection. It must remain fully operable, and after depressurization its external tightness is verified, particularly around the stem packing and pivot seal.

Successfully passing the Fire Safe test gives customers confidence that the valve is suitable for processes where a fire could result in the release of flammable or otherwise hazardous media. A Fire Safe certified valve helps reduce the risk of fire escalation or explosion and contributes to the protection of personnel, process equipment, and the environment. Even after exposure to extreme temperatures, it retains its essential sealing and shut-off capabilities.